Inside Home - Basement

Interior Mitigation System:Through Interior of Home

System Description:

Typically one penetration hole is made in the concrete floor (slab) and exposing interior drain tile or a small pit is created beneath penetration.  Sometimes addition penetrations are needed.  PVC vent pipe is connected to the penetration(s) and is routed through closets, plumbing chases, or other routes to attic space, radon fan is installed in unconditioned attic, through the roof sheathing, using a pipe roof flashing. The radon gas is discharged safely above the roof. The PVC vent pipe protrudes a minimum of 12 inches above the roof and has the same appearance as a standard plumbing vent pipe.

Outside Attached Garage - Roof

DURING  - Installed protection membrane before poly sheeting

Inside Home - Attic

Inside Home - Closet

​​​​​Radon Mitigation Services


  Locally owned business that has been offering radon mitigation systems for Northern Minnesota and Wisconsin since 2007.   Specializing in radon mitigation system installations and pride ourselves on excellent customer service and quality craftsmanship on the design and installation of radon mitigation systems.  Working with home sellers and buyers during real estate transactions to make the process go smoothly during this exciting and sometimes stressful time.


Seal Required Areas:​​


Sump Basin Lids​​  |  Slab Cracks​  |  Slab Openings​  | Cold Joint Seams  |  Crawl Spaces

Exterior Mitigation System:

System Description:
Typically one penetration hole is made in the concrete floor (slab) and exposing interior drain tile or a small pit is created beneath penetration.  Sometimes addition penetrations are needed.  PVC vent pipe is connected to the penetration(s) and is routed unobtrusively through the rim joist to the outside, where the radon fan is installed,  vent line routed up the sidewall of the house to discharge the radon gas safely above the roof. 

Interior Mitigation System:Through Attached Garage

System Description:

Typically one penetration hole is made in the concrete floor (slab) and exposing interior drain tile or a small pit is created beneath penetration.  Sometimes addition penetrations are needed.  PVC vent pipe is connected to the penetration(s) and is routed through the rim joist to the attached garage, routed up wall, radon fan is installed in attic, then vented through the roof sheathing, using a pipe roof flashing. The radon gas is discharged safely above the roof. The PVC vent pipe protrudes a minimum of 12 inches above the roof and has the same appearance as a standard plumbing vent pipe.

Inside Attached Garage - Attic

BEFORE  - Loose / unsealed seams poly sheeting to be removed

Crawl Space  -  Project Two

Inside Home - Basement

Crawl Space  -  Project One

Inside Attached Garage - Fire Collar

AFTER - Installed poly sheeting with sealed seams

Outside -Sample One

Radon Retarders & Vapor Barriers​ - Crawl Space

AFTER - Installed reinforced poly sheeting with sealed seams

​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​Specializing in Radon Mitigation / Reduction